The brain4care app can be downloaded and installed from the Google Play Store or Apple App Store through the by following these steps:

Android (Google)

iOS (Apple)

Step 1 - app store: On your mobile device click on , open the app store for the respective your operating system , (iOS or Android).

Step 2 - Search for the app:Click on Tap the search bar and search for the brain4care enter "brain4care" to find the app.

Step 3 - app selection: Click on Select the brain4care app that will appear in the listfrom the search results.

Step 4 - installation: On the next screen, click INSTALL or GET.

Step 5 - Open the app: After downloading and installing the app, click OPEN.

Note

CAUTION - Make sure your mobile device is configured with a strong password; do not use it in root mode, nor with unverified apps installed

Step 6 - GPS permission: For the correct To ensure proper functioning of the B4C System, it is necessary to allow device you must enable location access for the device.

Step 7 - make sure Bluetooth is active: To use the brain4care system, make sure that ensure Bluetooth is turned on, if . If it’s not, turn enable it on in the your device settings.

Step 8 - corporate access account: To use the brain4care app, you must have a brain4care account.

Your corporate account manager must create and enable your user to use account for the application and system. For details, consult technical support or refer to the Portal Manual.

Info

ATTENTION - The device must not be set to power saving mode as this may affect the performance and functionality of the mobile device and mobile app.

...

Info

ATTENTION - It is recommended to keep the original packaging in case the equipment needs to be transported. Misuse of the product will void the warranty.

When selecting the a location for using the B4C System, consider the operating temperature, brightness, power outlets (if a multi parameter monitor that requires the use of a power outlet is used), and the space for movement of professionals and patientsthe following:

  • Operating Temperature: Ensure it is within the recommended range.

  • Brightness: Choose an area with appropriate lighting.

  • Power Outlets: Ensure availability if using a multiparameter monitor that requires power.

  • Space: Allow sufficient room for both professionals and patients to move.

The system should be used in a climate-controlled location environment, with temperature, humidity, and pressure within the environmental specifications given outlined in section https://brain4care.atlassian.net/wiki/spaces/B4CSENSORGUIDE30/pages/3220244556/4+technical+characteristics#4.2-environmental

For transportation or storage of the equipment, ensure environmental conditions must be maintained remain within the temperature, humidity, and pressure tolerance range defined again ranges specified in section https://brain4care.atlassian.net/wiki/spaces/B4CSENSORGUIDE30/pages/3220244556/4+technical+characteristics#4.2-environmental.

The equipment must be installed and used in an electromagnetic environment in accordance with the information as described in annex 3 - electromagnetic safety standards. The user must ensure that it is used in such an environment.

Portable and mobile RF communication equipment may affect impact the product and should therefore be kept at a calculated . Maintain a distance as defined in Table 3-3 in section specified in annex 3 - electromagnetic safety standards.

In coastal cities, attention should be paid to the damage that can be caused by salt spray . It is recommended to install the necessary equipment (air conditioner and dehumidifier) to maintain the ideal conditions for the equipment.

Equipment (especially the sensors) must not be exposed to sunlight.

To facilitate can cause damage. Install equipment like air conditioners and dehumidifiers to maintain optimal conditions.

Ensure the equipment, particularly the sensors, is not exposed to direct sunlight.

For accurate monitoring, the patient should lie or sit remain still during a monitoring the session.

Do not wet Avoid wetting the sensor nor let or allowing it to come into contact with chemicals and / or flammables flammable substances that could cause damage it.

Warning

WARNING - Do not leave the equipment near flammable chemicals such as alcohol, benzene, etc. Should they come in contact with electrical parts, this may result in fire or internal short circuit. The same is true with the use of some flammable disinfectants.

...

The BcSs-PICNIW-2000 sensor has one features a single internal battery and is charged via an inductive charger. It is not possible to use the product while the battery is being chargedThe sensor cannot be used while charging.

The BcSs-PICNIW-1000 sensor is powered by operates with two lithium-ion batteries: one internal and another one external removable battery. The first, with smaller capacity has enough autonomy internal battery provides sufficient power to keep the sensor running operational while the removable external battery is being charged , disconnected from the sensorseparately.

For charging instructions please go to 6.11 charging sensor battery section.

...

The patient environment is the place where diagnostics, monitoring, or treatments occur and as such intentional and unintentional contact can occur between a PATIENT , involving potential contact between the patient and parts of Electromedical Equipment or Electromedical Systemelectromedical equipment or systems, or between a PATIENT and other people in contact with Electromedical Equipment of Electromedical Systemthe patient and individuals handling the equipment.

The BcSs-PICNIW-2000 sensor, BcSs-PICNIW-1000 sensor and its , external battery (BcAc-BATEX-1000), headbands kit (BcAc-AF-1000), and receiver module (BcAc-DG-1000) are adequate designed for safe use in this environment.

Please refer to 12 technical documentation and annex 3 - electromagnetic safety standards.

...